The IUD procedure includes steps such as bimanual examination, routine sterilization, probing the depth of the uterine cavity, and placing the IUD. Specific operations should be carried out by specialized doctors.
1. Duplex examination: to find out the size and position of the uterus and the condition of the adnexa.
2. Routine disinfection: the vulva and vagina are routinely disinfected with iodine povidone, and then the vagina is opened with a vaginal speculum to expose the cervix and then disinfect the cervix and cervical canal.
3. Detection of the depth of the uterine cavity: the anterior lip of the cervix is clamped with a cervical forceps, and a uterine probe is used to detect the depth of the uterine cavity in line with the position of the uterus.
4. Placement of IUD: After detection, the IUD is pushed into the uterine cavity with the placer. The upper edge of the IUD must reach the bottom of the uterus, and the IUD with a tailed wire needs to be cut off, and finally the cervical forceps and vaginal speculum are withdrawn under observation that there is no obvious bleeding.
If you need an IUD, please go to a regular hospital to have it placed.